Cluster Expansion Runbook — adding hosts to an existing cluster

Adding hosts to an existing, non-stretched cluster to grow its capacity. A new cluster is 24-cluster-creation.md; stretching an existing cluster across AZs is a different operation, covered in 22-stretch-execution.md.

The documented click-path for this operation runs through the vSphere Client, same as 24-cluster-creation.md (Create SDDC Cluster) and 23-workload-domain-creation.md (Add workload domain, from VCF Operations) — none of the three runbooks in this set use SDDC Manager’s own UI as the primary route, which is deprecated in VCF 9 (see CLAUDE.md). Broadcom’s own page notes “you can instead perform this task using the SDDC Manager UI” as a still-working alternative during the deprecation window, but does not document that alternative’s click path — treat the vSphere Client flow below as the supported, documented UI route.

The underlying SDDC Manager API is fully reference-documented, though (PATCH /v1/clusters/{clusterId} with ClusterExpansionSpec), and it’s the only documented path to a handful of options the vSphere Client wizard doesn’t expose at all — see §3 below.


The sequence, end to end

network pool has room  →  commission the host  →  add it (vSphere Client)
      (manual)                (manual)              Actions > Add Hosts

1. Manual — before you add anything

Cluster converged or imported with NFS 4.1, iSCSI, FCoE or NVMe-oF as principal storage? §1–§3 don’t apply: those hosts can’t be commissioned. Go to §5.

  • The host must match the existing cluster’s configuration: same principal storage type, and — per Broadcom — “the ESX host to be added matches the configuration of the ESX hosts already in the SDDC cluster.” Different NIC enumeration is allowed (a host doesn’t need vmnic0/1 in the identical physical slot), but the storage type must match exactly.
  • If this cluster’s NSX Host Overlay uses a static IP pool, confirm it has enough free addresses for the hosts you’re adding before you start — the wizard does not grow the pool for you.
  • Image and commission the host into SDDC Manager first (same network pool as the existing cluster) — use VCFHostPreparation to prep and commission quickly. It must show as unassigned and active in the Hosts inventory.
  • vSAN stretched clusters cannot use a shared vDS — if this cluster is stretched, don’t route this expansion through a vDS-reuse path meant for non-stretched clusters.
  • 9.1.1+ vDS limits still apply: adding a host to a cluster on a shared vDS keeps you under 128 vDS per vCenter / 16 per ESX host — same ceiling as 24-cluster-creation.md’s vDS-reuse rules.
  • You need the right vSphere Client. TechDocs: “To perform this task in the vSphere Client, you must have access to the management domain vCenter, or your VCF Instance must be configured with VCF SSO and vCenter linking.” The same prerequisite applies to 24-cluster-creation.md. See the note under §2 for what that means for a workload domain.

2. Add the host — vSphere Client

Workload domain cluster and no Add Unassigned Hosts menu? Broadcom KB 442933 says: “Add Unassigned Hosts option is not available the Workload Domain vCenter”. It describes the standard method as the vSphere Client “from the Management vCenter UI”. That matches the TechDocs prerequisite in §1. In VCF 9 a workload domain’s vCenter is not in Enhanced Linked Mode with the management vCenter, so to reach a workload-domain cluster from a vSphere Client that offers the wizard you need VCF SSO + vCenter linking (VCF Operations → Operate → Administration Configuration → vCenter Linking; Linking vCenter Instances in VCF Operations: a common identity provider on all vCenters, no ELM group, 2–15 vCenters per group; fleet SSO setup is 12-sso-configuration.md). Without linking, use the API (§3). The KB’s other suggestion, the SDDC Manager UI, still works during the deprecation window but is deprecated in VCF 9 (see the intro), so treat it as a last resort.

  1. Open the vSphere Client of the management domain vCenter (or any linked vCenter, once VCF SSO + vCenter linking are configured) and browse to the vSphere cluster in the inventory.
  2. Select the cluster → Actions → Add Hosts → Add Unassigned Hosts.
  3. Select the commissioned host(s) to add → Next.
  4. Review the proposed switch/network configuration → Next.
  5. Review host, switch configuration, and license details → Finish.

What the wizard automates for you, by storage type:

  • NFS and vVols (vVols deprecated as of VCF/VVF 9.0 — see 02-intake.md H6) — storage is auto-configured and mounted; no manual datastore steps.
  • VMFS on FC — storage is not automatic: you handle zoning, mounting the volume, and datastore creation yourself before or alongside the host add.
  • Any type — uplinks are assigned and the host is connected to the cluster’s vDS (shared or otherwise) automatically.

3. Add the host — API (scripted alternative)

PATCH /v1/clusters/{clusterId} carrying a ClusterExpansionSpec, validated first via POST /v1/clusters/{clusterId}/validations — same validate-then-submit pattern as the other three runbooks.

Building the JSON by hand

  • Cluster ID. GET /v1/clusters, copy the id of the cluster you’re expanding.
  • Host ID(s). GET /v1/hosts with status=UNASSIGNED_USEABLE, copy the id for each commissioned host from §1 above.

Trimmed example (1 host) — field names verified against the VCF API reference’s ClusterExpansionSpec:

{
  "hostSpecs": [
    {
      "id": "<host ID>",
      "licenseKey": "<ESXi license key, or omit with deployWithoutLicenseKeys>",
      "hostNetworkSpec": {
        "vmNics": [
          { "id": "vmnic0", "vdsName": "sfo-w01-cl01-vds01", "uplink": "uplink1" },
          { "id": "vmnic1", "vdsName": "sfo-w01-cl01-vds01", "uplink": "uplink2" }
        ],
        "networkProfileName": "sfo-w01-cl01-network-profile01"
      }
    }
  ],
  "networkSpec": {
    "nsxClusterSpec": { "...": "cluster-expansion-specific NSX config — ClusterExpansionNsxSpec, same idea as the stretch/creation runbooks' nsxClusterSpec but its own type" },
    "networkProfiles": [ "<ClusterExpansionNetworkProfile — same idea as networkProfiles elsewhere, its own type>" ]
  },
  "deployWithoutLicenseKeys": true
}

Field-by-field, the parts specific to expansion:

  • hostSpecs[] — 1-64 hosts per call (minItems: 1, maxItems: 64). Same hostNetworkSpec.vmNics[] shape as the creation/stretch/ domain-creation specs: mirror the existing cluster’s vmnic-to-vDS mapping exactly, or the host fails to join.
  • networkSpec is ClusterExpansionNetworkSpec — a distinct type from the NetworkSpec used by ClusterCreationSpec/DomainCreationSpec, even though nsxClusterSpec and networkProfiles mean the same thing conceptually. Don’t assume the exact field names from 23-workload-domain-creation.md §5 carry over unchanged — check the linked reference for this call specifically before submitting.
  • witnessSpec / witnessTrafficSharedWithVsanTraffic / vsanNetworkSpecs (not shown above) — only relevant if this cluster is stretched, which §1’s precondition list already rules out for this runbook (“vSAN stretched clusters cannot use a shared vDS”). If you’re expanding a stretched cluster instead, use 22-stretch-execution.md’s field-by-field breakdown of the equivalent fields on clusterStretchSpec as your reference for these three.
  • interRackExpansion — “Is inter-rack cluster expansion (L2 non-uniform/L3 vs. L2 uniform). Required for clusters with NSX Edge Cluster.” Set this if the hosts you’re adding sit in a different rack/L2 segment than the cluster’s existing hosts and this cluster hosts an NSX Edge cluster — easy to miss because nothing in the vSphere Client wizard surfaces this concept at all.
  • deployWithoutLicenseKeys — same field and guidance as the other three runbooks: leave true unless you specifically want the call to hard-fail on a missing license key.
  • forceHostAdditionInPresenceofDeadHosts / skipThumbprintValidation — both deprecated, no effect when used per the API reference; don’t rely on either even though they still appear in the spec.

4. Acceptance

  • Host shows connected in the cluster, matching build/patch level to its cluster-mates.
  • Storage healthy: for VMFS, the datastore you manually zoned/mounted is visible and consumed by the new host; for NFS/vVols, auto-mounted and visible.
  • If a static TEP IP pool was used: the new host received an address from it, not from overflow/DHCP fallback.

5. Converged / imported clusters on converge-only storage

Everything above assumes a principal storage type that host commissioning understands: vSAN, NFS, VMFS on FC or vVol. A cluster that was converged (management domain) or imported (workload domain) with NFS 4.1, iSCSI, FCoE or NVMe over Fabrics (TCP, FC, RDMA) as principal storage doesn’t fit that path. The commission wizard has no storage type to choose for it. So the §1 → §2 flow (commission → Add Unassigned Hosts) is not the route for these clusters. Why these storage types end up converge-only, and the other trade-offs, is in prerequisites.md → Principal storage.

Broadcom’s route: “for day 2 operations other than LCM such as host commissioning, adding hosts or clusters, removing hosts or clusters, first perform these operations in the respective vCenter and then run the ‘Sync Inventory’ operation” (KB 416270). KB 405095 explains why the SDDC Manager path fails on these clusters (“Cluster is marked as imported. This operation is not allowed on imported clusters”, or an Add Host wizard whose Next stays greyed out at “Selected resources: 0 Cores, 0 GB Memory, 0 GB Storage”), and gives the manual route: add the host in the vSphere Client, “ensuring configuration consistency (NTP, VMK, networking, NSX, storage)”. Each of those five is yours to get right, because nothing in VCF configures them for this host.

build host to match  →  storage by hand  →  add in vCenter  →  NSX + image  →  VCF picks it up
   (manual)              (manual, per type)    (vSphere Client)   (verify)        (9.0: Sync Inventory)

5.1 Build the host to match the cluster

Same checks as §1, plus what converge itself requires:

  • Same ESX build as the cluster’s vLCM image. Converge requires image-managed clusters (“Clusters using baselines for lifecycle management” are not supported), so the host has to be compliant with that image. Install the same build, and remediate against the cluster image after adding it if vCenter reports drift.
  • Same NIC layout and count. Hosts with more vmnics than their cluster-mates can’t use the extras: “1 or more of those VMNICs will be unusable due to the requirements to maintain a uniform host image” (KB 442933).
  • Static VMkernel IPs for management, vMotion and storage. “Dynamically allocated VMkernel IP addresses” are on the converge not-supported list.
  • NTP, DNS (A + PTR, lowercase FQDN), syslog and the ESX root password set the same way as on the existing hosts. VCFHostPreparation covers the host-level basics, but stop short of commissioning.

5.2 Configure the principal storage by hand

The host must see the same datastore as its cluster-mates before it joins, over the same kind of path. Per type (vSphere 9.0 Storage docs):

Storage typeOn the new hostOn the array / fabric
iSCSIEnable the software iSCSI adapter; create one VMkernel per pNIC (1:1) on the storage port groups and bind them to the adapter (port binding); add the same dynamic/static targets and CHAP settings as the other hosts; rescanAdd the new host’s IQN to the initiator group / LUN masking. With port binding, “make sure that all target portals are reachable from all VMkernel ports” or sessions fail
NVMe/TCP, NVMe/RDMAVMkernel binding on the storage NICs, then add the software NVMe over TCP / RDMA adapter and discover / connect the controllers. RDMA also needs lossless EthernetAdd the host’s host NQN to the subsystem’s allowed hosts. NVMe/TCP does not support LACP / port-channel on the host links; multipathing does the HA
NVMe/FC, FCoEHBA / CNA with the same firmware + driver as the cluster-matesZoning + masking of the new host’s WWPNs / host NQN, as for VMFS on FC in §1
NFS 4.1Mount with the same server IP list (session-trunking multipathing) and the same security mode as the other hosts; for Kerberos, join the host to AD and set the NFS Kerberos credentials first (Create an NFS 4.1 Datastore)Add the new host’s storage VMkernel IP(s) to the export policy. AUTH_SYS and Kerberos can’t be mixed on one shared NFS 4.1 datastore

Then check it: the datastore appears on the new host with the same name and backing device / share, all expected paths are up (esxcli storage nmp device list for SCSI/NVMe devices), and MTU is correct end to end (vmkping -I <vmkX> -s 8972 -d <target-ip> for jumbo).

Don’t let the new host bring another datastore that its cluster-mates can also see (a stray NFS v3 mount, a shared VMFS LUN). VCF picks the principal datastore by type priority (“vSAN, NFS v3, VMFS, NFS 4.1, iSCSI, vVols”), and a newly common higher-priority datastore is not what you want it to find.

5.3 Add the host in the vSphere Client

  1. In the cluster’s vCenter: cluster → Actions → Add Hosts (the plain vCenter wizard: FQDN, root credentials, certificate). Not Add Unassigned Hosts, which lists only commissioned hosts.
  2. Add the host to the cluster’s vDS and migrate its VMkernels to the matching distributed port groups (management, vMotion, the storage VMkernels from §5.2), with the same uplink assignment as its cluster-mates.
  3. NSX: if the cluster has an NSX transport node profile attached, NSX prepares the host itself: “When you move an unprepared host into a cluster applied with a transport node profile, NSX automatically prepares the host as a transport node” (Transport Node Profiles). Check it reaches Success in NSX (System → Fabric → Hosts) and got a TEP address. If no profile is attached, prepare the host in NSX to match the others.
  4. vLCM: check the host is compliant with the cluster image; if not, remediate it (maintenance mode) before putting workloads on it.
  5. Exit maintenance mode.

5.4 Let VCF pick it up

  • 9.0: run Sync Inventory: VCF Operations → Inventory → VCF Instances → (domain) → Actions → Sync Inventory (KB 405095, KB 425835). Skip it and “lifecycle management in VCF Operations will be blocked for these hosts and clusters” (KB 416270). The CLI alternative on SDDC Manager is vcf_brownfield.py sync --domain-name '<domain-name>' in /opt/vmware/vcf/domainmanager/scripts/vcf-import-tool (KB 405095).
  • 9.1: KB 416270: “As of version 9.1 running ‘Sync Inventory’ in the VCF Operations console is no longer required.” Still check that the host shows up under the domain in VCF Operations before you call it done. KB 405095 (which covers 9.x generally) still lists the sync, so running it is a harmless fallback if the host doesn’t appear.
  • Root password: VCF Operations’ Password Management console doesn’t manage imported hosts’ ESX passwords. If you need the credential in SDDC Manager, KB 388859 (addEsxiRoot.py) adds it.

5.5 Removing a host again

Same principle, reversed. KB 405095’s manual steps: maintenance mode → move the host to the datacenter level in vCenter → remove NSX from it (NSX → System → Fabric → Hosts → Standalone/Other Nodes) → disconnect and remove from inventory → on 9.0, Sync Inventory. Then remove the host’s initiator / NQN / IP from the array’s access list.

TechDocs + KB-sourced, not yet field-verified in this repo.