Creating a new VI workload domain: the manual prep (network pool, commissioned hosts, DNS), then the creation wizard or API. This page expands 06-deployment-plan.md epic E9 (workload domain) into a linear runbook; its inputs are the Deploy Workload Domain sheet in workbook-cell-mapping.md (intake H1-H12). A new cluster added to an existing domain is 24-cluster-creation.md; adding hosts to an existing, non-stretched cluster is 25-cluster-expansion.md.

Creating a workload domain is mostly manual prep, unlike the stretch runbook’s single API call — SDDC Manager’s own procedure for this is a UI wizard, not an API-only flow. There is a JSON API path too (needed for LACP networking or a domain without a cluster), but it is not the primary documented route the way clusterStretchSpec is for stretching.

Want NFS 4.1, iSCSI, FCoE or NVMe-oF as this domain’s principal storage? This runbook doesn’t apply: host commissioning and the creation wizard/API only offer vSAN, NFS v3, VMFS on FC (and vVols). Those types are reachable only by building the vSphere cluster first and then running Add workload domain → Import a vCenter. The route and its drawbacks are in prerequisites.md → Principal storage; adding hosts to such a domain later is 25-cluster-expansion.md §5. TechDocs/KB-sourced, not field-verified (#366).


The sequence, end to end

network prep  →  commission hosts  →  DNS + image  →  create the domain
 (manual)         (manual)             (manual)         (wizard, or API)

1. Manual — network prep

From 01-network-dns-plan.md and this domain’s intake answers (H1-H4):

  • Per-domain VLANs/subnets: ESX Management, vMotion, vSAN (or your chosen principal storage), NSX Host Overlay (HOST TEP), VM Management.
  • A static IP pool or a DHCP server configured and advertising IP addresses on the workload domain’s NSX host overlay (HOST TEP) VLAN — TechDocs states this as a hard prerequisite; the wizard will not proceed without one or the other.
  • Build the network pool for this domain — same object and same ordering rule as the stretch runbook’s step 2: “A network pool with free IP addresses must be available” before you commission hosts, per Broadcom’s own prerequisite list. Same shape as intake H8: ESX Mgmt / vMotion / vSAN / vSAN Storage Client networks (VLAN / MTU / gateway / range).
  • If using Distributed connectivity (H4): the external VLAN every host in this domain attaches to, its gateway CIDR, the routable external IP block, and the /16 private transit-gateway block — see 01-network-dns-plan.md §B.

2. Manual — commission the hosts

  • Hosts must be commissioned with the target principal storage type — vSAN, NFS, VMFS on FC, or vVol (deprecated as of VCF/VVF 9.0 — see 02-intake.md H6; don’t default a new design to it). Mixing storage types within one cluster is not supported.
  • For vSAN: SSD/NVMe disks with no pre-existing partitions, and a vSphere Lifecycle Manager image already present in the VCF image library.
  • For vVols: a VASA provider added to the inventory first.
  • If the management domain hosts have an express patch applied, this domain’s hosts must be imaged with the same express patch.
  • Image with the supported ESXi ISO — VCFHostPreparation — configure the management network, DNS, NTP, root; then commission into SDDC Manager, into the network pool from step 1.

3. Manual — DNS records

Forward (A) + reverse (PTR) records for every appliance FQDN this domain will use: vCenter, NSX Manager appliances (1-3 + cluster), and — if Distributed connectivity — the VNA appliances. All must resolve before the wizard starts; it validates DNS live.

4. Create the domain — wizard (primary path)

VCF Operations, not SDDC Manager — SDDC Manager’s own UI is deprecated in VCF 9 (see CLAUDE.md). TechDocs-verified click-path: Operate → Overview → Inventory, expand VCF Instances and select your instance, then the Add workload domain dropdown → Create new → review prerequisites → Select All → Proceed. Deployment type “Full deployment with cluster” builds vCenter + NSX + the first cluster in one run; “Domain infrastructure only” builds vCenter + NSX with no cluster (hosts/cluster added later — this is also the only path if you need a domain with more than one vDS or hosts with more than two pNICs, which requires the API instead, see below).

Page by page:

  1. General Information — domain name (3-20 chars), deployment type, Enable vSphere Supervisor toggle, optional dual-stack networking, SSO domain name.

    Always use a new, separate SSO domain per workload domain — this isn’t really a “choice” to weigh with the architect, it’s the standard answer. A new SSO domain “creates a workload domain that is isolated from the other workload domains in your VCF instance”, and that isolation is what you want by default. Name it vsphere.local rather than something domain-specific — KISS: one name to remember across every domain, matching TechDocs’ own examples, instead of a naming scheme to invent and keep consistent. See 02-intake.md H2.

  2. vCenter — FQDN, IP, gateway (H2).
  3. Cluster — name, vLCM-images checkbox, vSphere Zone name.
  4. Image — pick from the image catalog, or extract one from a reference host.
  5. Networking — join an existing NSX Manager or deploy a new one (deployment size, appliance size, FQDNs); VPC network config (Full Stack vs VLAN-backed); Centralized vs Distributed connectivity (H4) — if Distributed: VLAN, gateway CIDR, external IP block, private transit block, VNA cluster.
  6. Storage — principal storage type, then the matching sub-page (vSAN cluster type/encryption/FTT/space-efficiency; NFS datastore+server; FC datastore; or vVol protocol/provider/container).
  7. Hosts — select from the ESX hosts commissioned in step 2 for this storage type.
  8. vSphere Distributed Switch — a profile (Default, Storage Separation, NSX Separation, Combined Separation, or Custom) mapping traffic types to uplinks/LAGs.
  9. vSphere Supervisor (only if enabled in step 1) — Supervisor name, Service CIDR, management network, NSX project, VPC connectivity profile, private CIDR ranges, workload DNS/NTP.

    Enabling Supervisor here has a consequence later, not now: “After the workload domain deployment is complete, you must deploy an NSX Edge cluster with a Tier-0 gateway to complete Supervisor activation, unless you are using an existing NSX Manager instance with a compatible NSX Edge cluster.” Plan the Edge cluster into the same delivery window (06-deployment-plan.md E6) — Supervisor won’t finish activating without it.

What the wizard builds for you: the vCenter instance, the NSX Manager instance (new or joined), the vSphere cluster, the vDS(es), the datastore(s), and Supervisor if enabled.

5. Create the domain — API (LACP, no-cluster, or scripted)

Needed instead of the wizard when: the domain needs more than one vDS, hosts have more than two pNICs or a single pNIC (see 29-single-pnic-build.md), you want LACP uplink teaming, or you’re building “Domain infrastructure only” (no cluster) for later expansion. The spec is DomainCreationSpec, validated first and then submitted, like the stretch runbook (which PATCHes an existing cluster; domain creation POSTs a new domain): POST /v1/domains/validations → POST /v1/domains (SDDC Manager API 9.1.1 — Domains).

Building the JSON by hand

Same two lookups as the stretch runbook, plus one more specific to domain creation:

  • Host IDs. GET /v1/hosts with status=UNASSIGNED_USEABLE, copy the id for each commissioned host (step 2 above).
  • Cluster image ID. From the image catalog you picked in the wizard’s equivalent step — GET /v1/releases or the image-management endpoints, copy the id for clusterImageId.
  • NSX license key — nsxTSpec.licenseKey below; not needed at all if deployWithoutLicenseKeys: true.

Trimmed example (2 hosts, one cluster, vSAN principal storage) — field names and nesting verified against the VCF API reference’s DomainCreationSpec and its nested types:

{
  "domainName": "sfo-w01",
  "orgName": "sfo",
  "vcenterSpec": {
    "name": "sfo-w01-vc01",
    "networkDetailsSpec": {
      "ipAddress": "10.11.14.10",
      "dnsName": "sfo-w01-vc01.sfo.rainpole.io",
      "gateway": "10.11.14.1",
      "subnetMask": "255.255.255.0"
    },
    "rootPassword": "VMw@re1!VCF",
    "datacenterName": "sfo-w01-dc01",
    "vmSize": "medium",
    "storageSize": "lstorage"
  },
  "computeSpec": {
    "clusterSpecs": [
      {
        "name": "sfo-w01-cl01",
        "clusterImageId": "<image catalog ID>",
        "hostSpecs": [
          {
            "id": "<host 1 ID>",
            "licenseKey": "<ESXi license key, or omit with deployWithoutLicenseKeys>",
            "hostNetworkSpec": {
              "vmNics": [
                { "id": "vmnic0", "vdsName": "sfo-w01-cl01-vds01", "uplink": "uplink1" },
                { "id": "vmnic1", "vdsName": "sfo-w01-cl01-vds01", "uplink": "uplink2" }
              ],
              "networkProfileName": "sfo-w01-cl01-network-profile01"
            }
          },
          { "id": "<host 2 ID>", "...": "same shape as host 1" }
        ],
        "datastoreSpec": {
          "vsanDatastoreSpec": {
            "datastoreName": "sfo-w01-cl01-ds-vsan01",
            "failuresToTolerate": 1,
            "licenseKey": "<vSAN license key, or omit with deployWithoutLicenseKeys>"
          }
        },
        "networkSpec": {
          "vdsSpecs": [
            {
              "name": "sfo-w01-cl01-vds01",
              "mtu": 9000,
              "portGroupSpecs": [ "<one entry per traffic type — same idea as the wizard's vDS profile page>" ]
            }
          ],
          "nsxClusterSpec": { "...": "ipAddressPoolsSpec + uplinkProfiles — identical shape to the stretch runbook's nsxClusterSpec" },
          "networkProfiles": [
            {
              "name": "sfo-w01-cl01-network-profile01",
              "isDefault": true,
              "nsxtHostSwitchConfigs": [ "<binds the profile to the vDS + pool/uplink profile by name — see the stretch runbook>" ]
            }
          ]
        }
      }
    ]
  },
  "nsxTSpec": {
    "nsxManagerSpecs": [
      { "name": "sfo-w01-nsx01a", "networkDetailsSpec": { "...": "IP/gateway/DNS, same shape as vcenterSpec's" } },
      { "name": "sfo-w01-nsx01b", "...": "same shape" },
      { "name": "sfo-w01-nsx01c", "...": "same shape" }
    ],
    "vipFqdn": "sfo-w01-nsx01.sfo.rainpole.io",
    "licenseKey": "<NSX license key, or omit with deployWithoutLicenseKeys>",
    "nsxManagerAdminPassword": "VMw@re1!VCF",
    "formFactor": "medium"
  },
  "ssoDomainSpec": {
    "ssoDomainName": "vsphere.local",
    "ssoDomainPassword": "VMw@re1!VCF"
  },
  "deployWithoutLicenseKeys": true
}

Field-by-field, the parts that aren’t self-explanatory or that overlap with the stretch runbook:

  • vcenterSpec — one vCenter appliance per domain, always. vmSize / storageSize are the same tiering choice as the bring-up vCenter (tiny/small/medium/large/xlarge; lstorage/xlstorage) — size it against the domain’s expected inventory, not just copy the management domain’s.
  • computeSpec.clusterSpecs[].hostSpecs[] — one entry per commissioned host from step 2. hostNetworkSpec.vmNics[] is the wizard’s page-8 vDS profile, expressed per host instead of picked from a dropdown — get the uplink-to-vDS mapping wrong here and the host fails to join the vDS, exactly like the stretch runbook’s hostSpecs[].hostNetworkSpec.vmNics.
  • computeSpec.clusterSpecs[].datastoreSpec — pick the block matching your principal storage type: vsanDatastoreSpec (shown), nfsDatastoreSpecs[], vmfsDatastoreSpec, or vvolDatastoreSpecs[] — only one applies per cluster, matching the wizard’s step-6 branch. failuresToTolerate is vSAN OSA-only; vSAN ESA clusters use esaConfig instead.
  • computeSpec.clusterSpecs[].networkSpec.vdsSpecs[] — one entry per vDS; this is the field that makes the API path mandatory for a more-than-one-vDS domain, since the wizard’s vDS profile page only builds one. mtu applies per vDS, not per uplink.
  • networkSpec.nsxClusterSpec and networkSpec.networkProfiles[] — identical shape and gotchas to the stretch runbook’s networkSpec (the AZ2 TEP pool + sub-TNP profile) — see 22-stretch-execution.md for the field-by-field breakdown of ipAddressPoolsSpec, uplinkProfiles[], and nsxtHostSwitchConfigs[]. The one difference here: networkProfiles[].isDefault is always true for a new domain’s first (and normally only) network profile — there’s no management-vs-workload split to make, because this is the domain’s cluster being created fresh, not a stretch being added to one that already has a default profile.
  • nsxTSpec.nsxManagerSpecs[] — 1 appliance for a small/compact deployment or 3 for a standard HA cluster, same choice as page 5’s “deploy a new one” branch. vipFqdn (shown) or vip — TechDocs: “Can be omitted if FQDN is provided” — provide one or the other, not necessarily both.
  • ssoDomainSpec — per the corrected guidance in step 4 above: always ssoDomainName: "vsphere.local", never a domain-specific name. Omitting ssoDomainSpec entirely joins an existing SSO domain instead of creating a new, isolated one — don’t omit it unless that’s deliberately what you want.
  • deployWithoutLicenseKeys — same field and same guidance as the stretch runbook: leave true unless you specifically want the call to hard-fail on a missing license key. With it true, every licenseKey field above can be omitted.
  • securitySpec (not shown) — optional; only needed to set non-default password-complexity or account-lockout policy at creation time rather than after the fact in vCenter/NSX directly.

vcenterSpec, computeSpec, and nsxTSpec are each large, deeply-nested objects (per-host vmnic mappings, per-vDS uplink profiles, NSX transport zones) — the same category of detail the stretch runbook’s hostSpecs / nsxClusterSpec cover, multiplied across every host and network in the domain. Hand-building the full JSON is realistic but long; the practical path is VCFJsonSpecCreators’s New-VCFWorkloadDomain.ps1 (06-deployment-plan.md Story 9.3 already references it), which assembles the nested specs from simpler inputs, validates, and submits. Reach for the raw JSON only for the LACP or without-a-cluster variants where the wizard doesn’t reach.

6. Acceptance

  • WLD healthy in SDDC Manager: vCenter and NSX Manager reachable and green.
  • First cluster (if created) online, storage healthy for the chosen principal type.
  • North-south reachable per the connectivity model chosen (H4) — Centralized: Tier-0 + BGP routes; Distributed: DTGW on the external VLAN, fabric routing confirmed.
  • With Supervisor enabled: connectivity prerequisites met, ready for the NSX Edge cluster / Tier-0 step if using a new NSX Manager instance.