Cluster Creation Runbook — adding a cluster to an existing workload domain

Adding a cluster to a domain that already exists: network pool and commissioned hosts, then the Create SDDC Cluster wizard or the API. This page expands 06-deployment-plan.md epic E9, story 9.3 (the New-VCFClusterSpec.ps1 reference). Creating the domain and its first cluster together is 23-workload-domain-creation.md; adding hosts to an existing cluster is 25-cluster-expansion.md.

Broadcom’s documented click-path for this runs through the vSphere Client, not SDDC Manager — the same shape as 25-cluster-expansion.md: you browse to the domain’s vCenter and drive the wizard from there. TechDocs is explicit that the SDDC Manager UI (deprecated in VCF 9 — see CLAUDE.md) is the alternative here, not the primary route: “Additionally, you can perform this task using the SDDC Manager UI.” There is also no dedicated 9.1 API walkthrough page for adding a cluster (there was one for older VCF versions, but it isn’t carried forward in the current docs set). The underlying API endpoint itself is still live and reference-documented (POST /v1/clusters with ClusterCreationSpec) — it’s what VCFJsonSpecCreators’s New-VCFClusterSpec.ps1 drives — so section 3 below covers it as the scripted alternative: vSphere Client for a normal, click-through delivery; API for LACP, multi-vDS, EVC/HA settings the wizard doesn’t expose, or scripted/repeatable delivery.


The sequence, end to end

network pool  →  commission hosts  →  create the cluster (vSphere Client)
 (manual)          (manual)             one wizard, ~6 pages

1. Manual — network pool and commissioned hosts

New cluster on NFS 4.1, iSCSI, FCoE or NVMe-oF as principal storage? This runbook doesn’t apply: those hosts can’t be commissioned, and the wizard’s Storage Type page only offers vSAN, NFS v3, VMFS on FC (and vVols). Every cluster on one of those types repeats the build-then-import route, and in the management domain iSCSI and NVMe are supplemental only for additional clusters. See prerequisites.md → Principal storage; host prep for such a cluster is 25-cluster-expansion.md §5. TechDocs/KB-sourced, not field-verified (#366).

  • The network pool and the hosts you’re adding must already exist — same ordering rule as 22-stretch-execution.md and 23-workload-domain-creation.md: build the pool, then commission.
  • Image and commission the new hosts before this step — use VCFHostPreparation to prep and commission quickly.
  • Hosts must be in active state, commissioned, and use the same principal storage type as the cluster you’re creating.
  • If this cluster’s NSX Host Overlay uses DHCP rather than a static IP pool, a DHCP server must already be configured and advertising on that VLAN — the wizard does not configure DHCP for you.
  • You need access to the management domain vCenter (or VCF SSO with vCenter linking) to run the wizard against this domain.

Reusing an existing vDS (9.1.1+)

If you want the new cluster to join an existing vDS rather than get its own, four conditions all apply:

  • The source cluster (already on that vDS) and the new cluster must be in the same network pool and the same data center.
  • Neither cluster may be configured as a stretched cluster.
  • Total vDS count must stay under 128 per vCenter and 16 per ESX host — reusing a vDS doesn’t bypass these ceilings, it just avoids adding a new one.

Get any of these wrong and the wizard’s vDS step won’t offer the existing switch as a reuse target — it isn’t a soft warning, it’s a hard filter.

2. Create the cluster — vSphere Client

In the vSphere Client for the domain’s vCenter, browse to the VCF instance datacenter in the inventory, select it, then Actions → New Cluster → Create SDDC Cluster. TechDocs’ own prerequisite matches the note in §1 above, verbatim: “To perform this task in the vSphere Client, you must have access to the management domain vCenter, or your VCF Instance must be configured with VCF SSO and vCenter linking.”

  1. Storage Type — “Select the storage type for the SDDC cluster and click Begin.” Principal storage type: vSAN, NFS, VMFS on FC, or vVol (deprecated as of VCF/VVF 9.0 — see 02-intake.md H6; don’t default a new design to it). Each cluster in a multi-cluster domain can use a different type, as long as every host within that cluster matches.
  2. Cluster naming & image — “Enter a name for the SDDC cluster” and “Select a cluster image from the drop-down menu” (or extract from a reference host, same choice as workload domain creation).
  3. Storage configuration — the type-specific page matching what you picked on page 1 (“Enter the vSAN/NFS/FC/vVol Storage details and click Next”) — same sub-pages as 23-workload-domain-creation.md step 4.
  4. Host Selection — “select hosts for the SDDC cluster and click Next” — pick from the commissioned, matching-storage-type hosts from step 1 above.
  5. Distributed Switch — “Enter the Distributed Switch details and click Next” — create a new vDS, or reuse an existing one if the four conditions above are met.
  6. Review — “review the vSphere cluster details and click Finish.”

TechDocs also flags a remediation consequence worth planning for, not just approving through: “If the cluster image contains a different version of a vendor add-on or component than what is installed on the ESXi hosts you add to the cluster, the hosts will be remediated” during creation — budget time for that if your commissioned hosts weren’t imaged against the exact image you pick on page 2.

This flow has no “skip failed hosts” toggle or standalone validation page — those exist at the API level (computeSpec.skipFailedHosts in §3 below) and may exist in SDDC Manager’s own UI alternative, but the six vSphere Client pages above are all there is. If a host fails here, sort it out and remove/replace it rather than looking for a way to proceed around it.

3. Create the cluster — API (scripted alternative)

POST /v1/clusters carrying a ClusterCreationSpec, validated first via POST /v1/clusters/validations — same validate-then-submit pattern as the stretch and domain-creation runbooks.

Building the JSON by hand

Same lookups as 23-workload-domain-creation.md §5 — host IDs (GET /v1/hosts with status=UNASSIGNED_USEABLE) and the cluster image ID — plus one more:

  • Domain ID. GET /v1/domains, copy the id of the workload domain you’re adding this cluster to — ClusterCreationSpec is domain-scoped, not standalone.

Trimmed example (2 hosts, vSAN principal storage) — field names and nesting verified against the VCF API reference’s ClusterCreationSpec:

{
  "domainId": "<workload domain ID>",
  "computeSpec": {
    "clusterSpecs": [
      {
        "name": "sfo-w01-cl02",
        "clusterImageId": "<image catalog ID>",
        "hostSpecs": [
          {
            "id": "<host 1 ID>",
            "licenseKey": "<ESXi license key, or omit with deployWithoutLicenseKeys>",
            "hostNetworkSpec": {
              "vmNics": [
                { "id": "vmnic0", "vdsName": "sfo-w01-cl02-vds01", "uplink": "uplink1" },
                { "id": "vmnic1", "vdsName": "sfo-w01-cl02-vds01", "uplink": "uplink2" }
              ],
              "networkProfileName": "sfo-w01-cl02-network-profile01"
            }
          },
          { "id": "<host 2 ID>", "...": "same shape as host 1" }
        ],
        "datastoreSpec": {
          "vsanDatastoreSpec": {
            "datastoreName": "sfo-w01-cl02-ds-vsan01",
            "failuresToTolerate": 1,
            "licenseKey": "<vSAN license key, or omit with deployWithoutLicenseKeys>"
          }
        },
        "networkSpec": {
          "vdsSpecs": [
            { "name": "sfo-w01-cl02-vds01", "mtu": 9000 }
          ],
          "nsxClusterSpec": { "...": "ipAddressPoolsSpec + uplinkProfiles — identical shape to the stretch/domain-creation runbooks" },
          "networkProfiles": [
            { "name": "sfo-w01-cl02-network-profile01", "isDefault": true, "nsxtHostSwitchConfigs": [ "<binds the profile to the vDS + pool/uplink profile by name>" ] }
          ]
        },
        "advancedOptions": {
          "evcMode": "<EVC baseline, e.g. intel-icelake — omit to inherit the cluster default>",
          "highAvailability": { "enabled": true }
        }
      }
    ],
    "skipFailedHosts": false
  },
  "deployWithoutLicenseKeys": true
}

Field-by-field, the parts specific to cluster creation (everything else — hostSpecs[].hostNetworkSpec, datastoreSpec, networkSpec.vdsSpecs/ nsxClusterSpec/networkProfiles — is identical in shape and gotchas to 23-workload-domain-creation.md §5, since both specs nest the same ComputeSpec.ClusterSpec structure):

  • domainId — the one field this spec has that DomainCreationSpec doesn’t: which existing domain the cluster is added to. Get this from the domain-ID lookup above, not the domain name.
  • computeSpec.skipFailedHosts — lets the call proceed with whichever hosts pass pre-checks instead of blocking on one bad host; the vSphere Client flow in §2 has no equivalent toggle, this is API-only.
  • clusterSpecs[].advancedOptions — not exposed by the vSphere Client wizard at all. evcMode sets an Enhanced vMotion Compatibility baseline at creation time instead of configuring it after the fact in vCenter; highAvailability.enabled toggles vSphere HA on the cluster immediately rather than as a separate post-creation step. This is one of the concrete reasons to reach for the API path even when you don’t need LACP or a reused vDS.
  • networkSpec.vdsSpecs[] — one entry per vDS; to reuse an existing vDS (the four-condition check in §1 above) instead of creating a new one, reference the existing vDS’s name here rather than a new one — the API doesn’t have a separate “reuse” flag, reuse is just naming an object that already exists.
  • deployWithoutLicenseKeys — same field and guidance as the stretch and domain-creation runbooks: leave true unless you specifically want the call to hard-fail on a missing license key.

4. Acceptance

  • Cluster online in SDDC Manager, storage healthy for the chosen principal type.
  • Hosts joined, vDS configured (new or reused) and reachable across all configured traffic types.
  • If DHCP-backed Host Overlay: hosts have received TEP addresses from the DHCP server.